Generator Running Cost Calculator: Gas vs Propane vs Natural Gas

A small inverter generator costs about a dollar an hour to run on gasoline at full load. A 22 kW standby generator at half load burns about 2.5 gallons of propane an hour, or about 2.3 therms of natural gas — multiply by your local price; the calculator uses this week's EIA prices.

What does it cost to run your generator?

Fuel burn from manufacturer specs × the latest EIA fuel prices (2026-11-23). Natural gas uses the rate on your gas bill.

Per hour–
Per 24 hours–
Per week–

Natural gas: ft³/h × 1,036 Btu/ft³ ÷ 100,000 Btu/therm (EIA heat content). Gasoline prices are EIA weekly retail averages, published for the U.S., regions and nine states; propane prices are EIA residential averages excluding taxes.

The formula

Cost per hour = fuel burned per hour × price per unit of fuel.

Fuel burn comes from the manufacturer’s specification. Standby generators publish consumption at 50% and 100% load; many portable generators publish runtime on a full tank instead, which we convert to gallons per hour. Prices come from the U.S. Energy Information Administration (EIA) weekly surveys. For natural gas, which is billed by the therm, the calculator converts cubic feet to therms using EIA’s average heat content.

What the numbers look like

Using EIA prices for the week of November 23, 2026 (U.S. averages: regular gasoline $3.642 per gallon, residential propane $2.813 per gallon):

Generator Fuel Burn rate Cost per hour Cost per 24 h
Honda EU2200i (1,800 W rated) Gasoline ~0.30 gal/h at rated load ~$1.09 ~$26
Honda EU7000iS (5,500 W rated) Gasoline ~0.78 gal/h at rated load ~$2.84 ~$68
Westinghouse WGen9500DF Gasoline ~0.83 gal/h at 50% ~$3.02 ~$73
Westinghouse WGen9500DF Propane ~0.67 gal/h at 50% ~$1.88 ~$45
Generac Guardian 22 kW Propane 2.53 gal/h at 50% ~$7.12 ~$171
Generac Guardian 22 kW Natural gas 221 ft³/h at 50% ~2.29 therms ~55 therms

The Honda figures are derived from Honda’s runtime specs (0.95 gallons for 3.2 hours, and 5.1 gallons for 6.5 hours, at rated load). The Westinghouse figures come from its runtime specs at 50% load. Generac publishes consumption directly.

Why gallons don’t compare directly

A gallon of gasoline holds about 120,214 Btu; a gallon of propane about 91,452 Btu (EIA). So the same engine burns more gallons of propane than gasoline to make the same power, and many dual-fuel portables are also rated a little lower on propane. A low propane price can still win on cost per hour, but not always — which is why the calculator compares fuels on cost per hour.

Natural gas is the easiest fuel to live with: it arrives by pipe, never goes stale and never runs out in a typical outage. The Generac 22 kW is rated at 21 kW on natural gas versus 22 kW on propane. At half load it burns 221 cubic feet per hour, about the same energy input as 2.53 gallons of propane. Whether that is cheaper depends on your utility’s rate; enter it from your bill.

Cost is only part of the fuel decision

  • Storage. Gasoline degrades in a few months without stabilizer; propane and natural gas do not. A generator that has to be drained after every season is one that may not start when you need it.
  • Availability during a disaster. Gas stations need power to pump. Propane deliveries can be delayed by storms. Utility natural gas is rarely interrupted by electrical outages, but it is not guaranteed after earthquakes or floods.
  • Runtime per refill. A portable generator’s tank lasts hours; a bulk propane tank lasts days. See the propane runtime calculator.
  • Power rating. Ratings change with fuel. Size for the fuel you will actually use with the generator size calculator.

Tips to lower running cost

  1. Don’t over-size. A generator far larger than your load burns more fuel per kilowatt-hour delivered. Size for your real peak with headroom, not for the whole house.
  2. Stagger big loads. Running the dryer, oven and water heater one at a time keeps the load in the efficient middle of the generator’s range.
  3. Use eco mode on inverter generators. Throttling down at light load is where inverter units save the most fuel.
  4. Shut down overnight when you can. A full refrigerator stays cold for hours with the door closed. Running in blocks instead of around the clock can cut fuel use substantially. Keep an eye on food safety and medical needs.
  5. Keep it maintained. Fresh oil and a clean air filter keep consumption close to the spec-sheet figures.

Safety

Every fuel-burning generator produces carbon monoxide. The U.S. Consumer Product Safety Commission warns never to run a portable generator inside a home or garage, even with doors open, and to keep it at least 20 feet from the house with the exhaust pointing away. Store gasoline in approved containers away from living spaces, and have a licensed professional install any connection to your home’s wiring or gas supply.

Worked example: a three-day outage

Suppose a winter storm knocks out power for three days and you run a Westinghouse WGen9500DF on gasoline at about half load, but only 16 hours a day, shutting down overnight. At about 0.83 gallons per hour that is roughly 40 gallons over the three days. At the U.S. average of $3.642 per gallon, the fuel costs about $145 — and you’d need to store or buy those 40 gallons safely. The same pattern on propane at about 0.67 gallons per hour uses about 32 gallons, roughly seven 20 lb cylinders, for about $90 at the U.S. average residential price. Either way, plan the fuel supply before the storm, when stations and exchange racks are still stocked.

Frequently asked questions

Is it cheaper to run a generator on propane or gasoline?

Per gallon, propane is often cheaper, but a gallon of propane holds less energy than a gallon of gasoline (about 91,452 Btu vs about 120,214 Btu per EIA), so a generator burns more gallons of propane for the same output. Compare cost per hour, not price per gallon — that is what the calculator does.

How do I convert natural gas consumption to therms?

Multiply cubic feet per hour by 1,036 Btu per cubic foot (EIA's average heat content) and divide by 100,000 Btu per therm. A generator burning 221 ft³/h uses about 2.29 therms per hour.

Where do I find my natural gas rate?

On your gas bill, usually as a price per therm (or per Ccf, which is close to one therm). Add delivery charges billed per therm to get your all-in rate.

Why does the calculator use one fuel figure for some portable generators?

Many portable generator makers publish runtime on a full tank at one load rather than a consumption table. We convert that runtime into gallons per hour and use it for every load, and say so in the result.

Does running a generator at low load save fuel?

It uses less fuel per hour, but more fuel per kilowatt-hour produced, because the engine keeps turning at speed. Inverter generators with an eco mode throttle down at light loads and save the most.

Sources

  1. U.S. Energy Information Administration — Gasoline and Diesel Fuel Update (accessed 2026-11-25)
  2. U.S. Energy Information Administration — Heating Oil and Propane Update (accessed 2026-11-25)
  3. U.S. Energy Information Administration — Units and calculators explained (heat content) (accessed 2026-11-25)
  4. Honda Power Equipment — EU2200i and EU7000iS specifications (accessed 2026-11-25)
  5. Generac — 22kW Standby Generator (7042) specifications (accessed 2026-11-25)

HomeBackupMath Editorial Team — Research & editorial

We build and maintain the calculators and guides on HomeBackupMath. Our work is based on manufacturer specification sheets and U.S. government data from the Energy Information Administration and federal safety agencies. Every page lists its sources, shows when its data was last checked, and is corrected when readers report errors. We do not publish hands-on product tests.