Home Battery Runtime Calculator: How Many kWh Do I Need?

Runtime is usable kWh ÷ average load. One 13.5 kWh Powerwall 3 runs an 800 W average load for about 15 hours with a 10% reserve. Covering a three-day outage at that load takes about 64 kWh — roughly five Powerwall-sized batteries without solar.

How long will a home battery run your house?

Enter your average load during an outage and the battery you're considering. Not sure of your load? Size it with our generator size calculator first.

Runtime–
Usable energy–
Units for your target–

Whole-home batteries such as Powerwall 3 are rated in AC kWh (energy delivered to the house), so efficiency defaults to 100%. Portable power stations are rated in battery Wh; inverter losses mean you get less at the outlet, so we default to 85% — check the manufacturer's figure. Runtime assumes no solar recharging.

Two numbers decide whether a battery works

A home battery has to pass two tests. The first is energy: enough kilowatt-hours to last through the outage. The second is power: enough kilowatts, at every moment, for everything running at once — including the brief surge when a motor starts. A battery can pass one test and fail the other. A large battery with a small inverter can run the fridge for days but trip when the well pump kicks on. A powerful battery with little storage starts the AC easily but runs out by morning.

The calculator checks both. Runtime comes from capacity and average load; the peak check compares your biggest moment with the battery’s continuous rating.

How runtime is calculated

Usable energy = capacity per unit × number of units × (1 − reserve) × efficiency. Runtime = usable energy ÷ average load.

  • Capacity. Tesla rates Powerwall 3 at 13.5 kWh; EcoFlow rates DELTA Pro 3 at 4,096 Wh.
  • Reserve. Most owners keep some charge back so the battery is never drained flat, or hold a storm reserve. We default to 10%.
  • Efficiency. Whole-home systems such as Powerwall 3 are rated in AC kWh — energy delivered to your panel — so efficiency defaults to 100%. Portable power stations are rated by battery capacity, so we default to 85% to allow for inverter losses.
  • Average load. This is the number people most often get wrong; see below.
Battery Usable at 10% reserve Runtime at 500 W at 800 W at 1,500 W
1 × Powerwall 3 (13.5 kWh AC) 12.2 kWh 24 h 15 h 8 h
2 × Powerwall 3 24.3 kWh 49 h 30 h 16 h
1 × DELTA Pro 3 (4.1 kWh, 85%) 3.1 kWh 6 h 3.9 h 2.1 h

Finding your average load

Average load is total energy over a day divided by 24 hours — not the wattage of your biggest appliance. A refrigerator might draw several hundred watts while its compressor runs, but it cycles on and off, so its average is far lower. Ways to estimate it:

  1. From your bill. Divide a month’s kWh by about 730 hours. A home using 900 kWh a month averages about 1,230 W. During an outage you’ll typically back up less than everything, so the real figure is lower.
  2. From your battery app or smart meter. Many utilities show hourly use. Look at a typical day with the AC or heat off for a realistic essentials baseline.
  3. Appliance by appliance. The U.S. Department of Energy suggests multiplying each appliance’s wattage by hours used per day, or measuring 120 V devices with an electricity usage monitor. Add them up and divide by 24.

The peak load is different: it is the most you’ll draw at once, such as the AC compressor starting while the fridge runs. Our generator size calculator adds up running and starting watts for you, and the same peak figure applies to batteries.

How many batteries for a long outage?

Outages are getting longer in many places. The U.S. Energy Information Administration reports that customers averaged about 11 hours without power in 2024, mostly because of hurricanes, and some states averaged far more. Check yours in our outage hours by state study.

To size for a target, the calculator inverts the formula: capacity needed = average load × hours ÷ (1 − reserve) ÷ efficiency. At 800 W, a 24-hour outage needs about 21 kWh of rated capacity; three days need about 64 kWh. That is why multi-day backup is usually built either with solar recharging the battery during the day, or with a generator.

Ways to stretch battery runtime

  • Back up essentials only. A dedicated backup panel with the fridge, lights, internet, furnace blower and a few outlets uses a fraction of a whole house’s energy.
  • Avoid resistive heat. Electric water heaters, ranges, dryers and space heaters draw 1,500–5,400 W each and drain a battery fast.
  • Add a soft starter to the AC. It reduces the start-up surge, so the battery’s power rating is less likely to trip, though it doesn’t reduce energy use while running.
  • Pair with solar. Even a partial day of sun can refill a meaningful share of a battery, turning a one-day system into a multi-day one in good weather.

Limits of this estimate

The calculator assumes a constant average load and no recharging. Real batteries also lose some capacity with age and in very cold or hot conditions, and some systems limit output when the battery is low. Use the result for planning, then ask your installer to confirm with your actual panel loads.

Worked example

A household wants to keep the refrigerator, a chest freezer, the gas furnace blower, internet, lights and phone charging running through a winter outage. Measured with a usage monitor and their utility app, those loads average about 600 W, with a peak of about 2,500 W when the freezer and blower start together. One Powerwall 3 with a 10% reserve gives about 12.2 kWh — roughly 20 hours at 600 W — and its 11.5 kW continuous rating covers the peak easily. Covering a full three-day outage would take about 48 kWh of rated capacity, or four Powerwall-sized batteries without solar.

Frequently asked questions

How long will a Powerwall 3 run my house?

Tesla rates Powerwall 3 at 13.5 kWh. At an average load of 800 W and a 10% reserve, that is about 15 hours; at 2,000 W, about 6 hours. Central air conditioning and electric heat shorten runtime dramatically.

What is the difference between kWh and kW?

kWh is energy — how long a battery can keep going. kW is power — how much it can deliver at once. A battery needs enough kWh for the outage length and enough kW (and motor-starting capability) for your biggest moment.

How do I find my average load?

Look at your utility bill: monthly kWh ÷ 730 hours gives your average draw. During an outage you'll run less, so backing up only essentials often brings it down a lot. An electricity usage monitor can measure individual 120 V appliances.

Why does the calculator reduce portable power station capacity?

Portable stations are usually rated by battery capacity, and converting DC to AC at the outlets loses energy. We default to 85% for those; whole-home batteries such as Powerwall 3 are rated in AC kWh, so they default to 100%. Use the manufacturer's figure if it publishes one.

Can a battery run a well pump or central AC?

Only if its continuous and motor-starting ratings cover the load. Tesla lists 11.5 kW continuous and 185 A LRA motor start for Powerwall 3; EcoFlow lists 4,000 W continuous and 8,000 W surge for DELTA Pro 3. Check your motor's nameplate.

Sources

  1. Tesla — How Powerwall Works (Powerwall 3 specifications) (accessed 2026-11-25)
  2. B&H Photo — EcoFlow DELTA Pro 3 specifications (accessed 2026-11-25)
  3. U.S. Department of Energy — Estimating Appliance and Home Electronic Energy Use (accessed 2026-11-25)
  4. U.S. Energy Information Administration — Hurricanes in 2024 led to the most hours without power in 10 years (accessed 2026-11-25)

HomeBackupMath Editorial Team — Research & editorial

We build and maintain the calculators and guides on HomeBackupMath. Our work is based on manufacturer specification sheets and U.S. government data from the Energy Information Administration and federal safety agencies. Every page lists its sources, shows when its data was last checked, and is corrected when readers report errors. We do not publish hands-on product tests.